Description
Table of Contents
Construction
Quality frame made from Ponderosa pine. Factory treated with a base preservative to reduce mould and mildew. Further treated with a coat of white paint for a clean white interior finish.
Wireless control
The VSS Solar Powered Skylight comes complete with a pre-programmed radio frequency controller for skylight operation. Externally mounted rain sensors automatically close the skylight once rain is detected**.
VELUX ACTIVE
Indoor climate control (sold separately)
VELUX Active operates on 2.4GHz and is compatible with modern ‘smart’ modems. (select the 2.4GHz channel in dual mode on your modem).
High Performance Double Glazing

Benefits:
- Radiant heat block: Complete window Glass only
- UV Harmful rays block approx 99%
- WERS rating 5 stars
- Double layer of Low-E³ coating.
- 10 year warranty on insulated glass seal.
- Reduced cleaning frequency.
Australian Standard AS1288
Laminated glass (standard with VSS) must be used
for skylights installed 3m or more above floor level.
NEAT™ Photocatalytic Coating
- Silicone Dioxide/Titanium Dioxide coating reacts with the sun’s UV rays to decompose surface organic dirt before rinsing away with the next shower of rain, thereby reducing cleaning frequency.
- The coating also makes the glass surface smoother, so water disperses evenly, sheets off, and evaporates quickly; thereby minimising water spotting on the pane.
* For roofs below 15° pitch, skylights need to be raised to 15° and custom flashed. VELUX can assist with technical advice and drawings. (NB: build-up not recommended in Bushfire areas.)
**Activation causes the skylight to close faster than normal operation.
Honeycomb blinds

- Adds a decorative effect.
- Colour: White on both sides.
- Materials: Double layered pleats (polyester) form a ‘honeycomb’ structure. Inner faces of honeycomb structure have aluminium coating. White powder-coated aluminium side channels and top cover.
- Provides near total light reduction.
- Reduce heat by approx 70%.^
- Easy to install.
Blackout blinds

- Colour: White on internal side. Silver coating on external side.
- Materials: Light-tight polyester with heat resistant coating. White powder-coated aluminium side channels and top cover.
- Provides near total light reduction.
- Reduce heat by approx 40%.†
- Easy to install.
Blinds sold separately.
EDW flashing

EDW flashing is used for skylights installed into tiled roofs and low profiled metal roofs (such as corrugated iron and spandek – not suitable for metal profiles such as Klip-Lok, Trimdek).
EDL flashing

EDL flashing is used for skylights installed into slate or shingle roofs – typically 4-8mm thick. ‘L’ shaped sections are provided that act as soaker pieces on either side of the skylight.
EKW combination flashing

Designed for installing multiple skylights side-by-side or above-below. Skylights must be spaced 100mm apart. EKW suitable for same roofs as EDW flashing.
NB: For roofs below 15° pitch, skylights need to be raised to 15° and custom flashed. VELUX can assist with technical advice and drawings. (NB: build-up not recommended in Bushfire areas.)
VCS – frame and glazing dimensions

Skylights can only be installed as per orientation depicted above.
NB: Opening Restrictors: NCC Vol 1 & 2 regulations (Prevention of Falls from Windows – Balustrades & Barriers): contact VELUX for information relating to restrictor devices for within-reach opening skylights.
‡ Weight includes flashing.
† Above-below combination installations require relocation of solar panel using relocation kit (supplied with skylight).
^ Based on VELUX internal testing with 3076 model Roof Window.
VCS technical performance
AS4285 SKYLIGHT– Cyclonic and Non-Cyclonic Tests | Pressure Rating –2.8kPa |
AS1288 OVERHEAD GLAZING | Laminated inner pane |
AS3959 BUSHFIRE | Attack Level 40^ |
NCC BOUNDARY SEPARATION† | Class 1 and Class 10 buildings: Within 900mm of a boundary wall Class 2 to Class 9 buildings: 3 metres from a boundary wall^^ |
BASIX Selection Guide
Timber, Low-E, Double glazed, Argon filled
VELUX Skylights are deemed non-combustible by CSIRO and thereby comply with NCC boundary separation requirements.
† CSIRO assessment report available on request. VELUX recommends consultation with relevant authority before work commences. Skylight assessed in closed position.
^ Roof pitch 18°-75°. Skylight only. Custom-made flashing required. Skylight tested in closed position, metal flywire mesh protection may be required for opening apertures (consult local council).
^^ Skylight cannot be closer than 3m unless the boundary is adjoining a road or public place. Consult NCC for further details.
* Not certified for NT DTCM.
VELUX Simulated Tests ††ASTM E822-2009.
†† ASTM E822-2009 standard practice for determining resistance of Solar Collector Covers to Hail impact with propelled ice balls. Hailstone test not performed on solar panel.
VSS Skylights have been energy rated in accordance with the Skylight Energy Rating Scheme (WERS).
Maximum 5 stars Summer Ratings
4.5 out of 5 stars for Winter Rating.
4.5 out of 5 stars for Cool Daylight in Summer.
U-value (W/m2K) | Complete skylight 2.5‡ Glass only 1.93 |
Solar Heat Gain Co-efficient | Complete skylight 0.21 Glass only 0.28 |
Visible Light Transmittance | Complete skylight 0.48 |
Luminous Efficacy (Ke = VT/SHGC) | Complete skylight 2.29 |
Acoustic performance | Complete skylight 32dB# |
Figures generated by AFRC accredited simulators. Figures based on complete skylight: nominal size 1275mm (W) x 1275mm (H).
‡ See required installation method overleaf.
# Based on Rw value tested to A1276.1.
Reviews
There are no reviews yet.